2.4 MM LPS L-DISTAL RADIAL PLATE RIGHT ANGLED
Select Side
Select HEAD HOLE
Select Shaft Hole
Rs.17,820.00
Choose Quantity
Product Details
Product Details:
The 2.4mm LPS L-Distal Radial Plate Right-Angled is an advanced orthopedic implant designed for treating distal radius fractures, specifically those that require right-angled fixation. The L-shaped design provides enhanced support and stability to the distal radius, ensuring precise bone alignment and optimal healing. This plate is ideal for trauma surgeries, offering surgeons a reliable solution for complex fractures requiring firm fixation.
The 2.4mm LPS L-Distal Radial Plate Right-Angled is an advanced orthopedic implant designed for treating distal radius fractures, specifically those that require right-angled fixation. The L-shaped design provides enhanced support and stability to the distal radius, ensuring precise bone alignment and optimal healing. This plate is ideal for trauma surgeries, offering surgeons a reliable solution for complex fractures requiring firm fixation.
Key Features:
- Right-Angled L-Shaped Design: Specifically designed for effective fixation of distal radius fractures, particularly those requiring an angular approach.
- Anatomically Contoured Plate: Pre-contoured to the natural anatomy of the distal radius for a perfect fit, reducing intraoperative bending.
- Multiple Locking and Non-Locking Screw Options: Provides flexibility in securing the fracture, with locking screws for greater stability in osteoporotic bone.
- Low Profile Design: Reduces soft tissue irritation and minimizes the risk of tendon impingement after surgery.
- Variable-Angle Locking System: Offers surgeons the ability to adjust the screw angle to suit the fracture and provide enhanced fixation.
- Durable and Biocompatible Materials: Available in corrosion-resistant stainless steel or titanium, ensuring long-lasting strength and safety.
- Right-Angled L-Shaped Design: Specifically designed for effective fixation of distal radius fractures, particularly those requiring an angular approach.
- Anatomically Contoured Plate: Pre-contoured to the natural anatomy of the distal radius for a perfect fit, reducing intraoperative bending.
- Multiple Locking and Non-Locking Screw Options: Provides flexibility in securing the fracture, with locking screws for greater stability in osteoporotic bone.
- Low Profile Design: Reduces soft tissue irritation and minimizes the risk of tendon impingement after surgery.
- Variable-Angle Locking System: Offers surgeons the ability to adjust the screw angle to suit the fracture and provide enhanced fixation.
- Durable and Biocompatible Materials: Available in corrosion-resistant stainless steel or titanium, ensuring long-lasting strength and safety.
Benefits:
- Precise Fracture Fixation: The right-angled, L-shaped design ensures the plate adapts well to the anatomical contours of the distal radius, providing secure fixation.
- Improved Bone Healing: Optimal stabilization ensures proper bone alignment, promoting faster recovery and reduced complication rates.
- Minimized Soft Tissue Irritation: Low-profile construction minimizes the chance of post-surgical irritation, enhancing patient comfort.
- Enhanced Flexibility for Surgeons: Locking and non-locking screw options, along with variable-angle locking, allow for customized fixation tailored to individual fracture patterns.
- Reduced Surgical Time: Pre-contoured design and multiple fixation options streamline the surgical process, saving valuable operating time.
- Increased Stability in Osteoporotic Bone: Locking screws provide additional stability for patients with weaker bones, making it suitable for various bone conditions.
- Precise Fracture Fixation: The right-angled, L-shaped design ensures the plate adapts well to the anatomical contours of the distal radius, providing secure fixation.
- Improved Bone Healing: Optimal stabilization ensures proper bone alignment, promoting faster recovery and reduced complication rates.
- Minimized Soft Tissue Irritation: Low-profile construction minimizes the chance of post-surgical irritation, enhancing patient comfort.
- Enhanced Flexibility for Surgeons: Locking and non-locking screw options, along with variable-angle locking, allow for customized fixation tailored to individual fracture patterns.
- Reduced Surgical Time: Pre-contoured design and multiple fixation options streamline the surgical process, saving valuable operating time.
- Increased Stability in Osteoporotic Bone: Locking screws provide additional stability for patients with weaker bones, making it suitable for various bone conditions.
Technical Specifications:
- Plate Thickness:2.4mm
- Material: Titanium, both corrosion-resistant and biocompatible.
- Screw Compatibility: Accepts 2.4mm and 2.7mm locking and non-locking screws.
- Locking Screw Holes: Multiple locking screw holes with variable-angle technology for secure fixation and flexibility in screw placement.
- Plate Lengths: Available in different lengths to accommodate various fracture patterns and surgical needs.
- Indications:Suitable for distal radius fractures, especially extra-articular fractures requiring right-angled fixation.
- Screw Angulation:Variable-angle locking system allows up to 15 degrees of screw angulation for optimal fixation.
- Sterilization Compatibility: Compatible with standard hospital sterilization methods.
- Contraindications: Not recommended for fractures involving the joint surface without joint-specific plates.
Ordering Information:
For detailed product codes, ordering information, and to find out more about how the Meril 2.4mm LPS L-Distal Radial Plate Right-Angled Plate can be integrated into your surgical practice, visit our website or contact a Meril representative.
- Plate Thickness:2.4mm
- Material: Titanium, both corrosion-resistant and biocompatible.
- Screw Compatibility: Accepts 2.4mm and 2.7mm locking and non-locking screws.
- Locking Screw Holes: Multiple locking screw holes with variable-angle technology for secure fixation and flexibility in screw placement.
- Plate Lengths: Available in different lengths to accommodate various fracture patterns and surgical needs.
- Indications:Suitable for distal radius fractures, especially extra-articular fractures requiring right-angled fixation.
- Screw Angulation:Variable-angle locking system allows up to 15 degrees of screw angulation for optimal fixation.
- Sterilization Compatibility: Compatible with standard hospital sterilization methods.
- Contraindications: Not recommended for fractures involving the joint surface without joint-specific plates.
Ordering Information:
For detailed product codes, ordering information, and to find out more about how the Meril 2.4mm LPS L-Distal Radial Plate Right-Angled Plate can be integrated into your surgical practice, visit our website or contact a Meril representative.
For detailed product codes, ordering information, and to find out more about how the Meril 2.4mm LPS L-Distal Radial Plate Right-Angled Plate can be integrated into your surgical practice, visit our website or contact a Meril representative.