3.5MM LPS MEDIAL PROXIMAL TIBIAL PLATE
Product Details
Product Details:
The 3.5mm LPS Medial Proximal Tibial Plate is an orthopedic implant specifically designed to stabilize and fixate fractures in the medial aspect of the proximal tibia. Its anatomical design and low-profile construction ensure optimal alignment, stability, and bone healing in complex fracture cases. This plate is widely used in trauma surgeries, providing orthopedic surgeons with a reliable implant for treating tibial fractures that require precise fixation on the medial side.
The 3.5mm LPS Medial Proximal Tibial Plate is an orthopedic implant specifically designed to stabilize and fixate fractures in the medial aspect of the proximal tibia. Its anatomical design and low-profile construction ensure optimal alignment, stability, and bone healing in complex fracture cases. This plate is widely used in trauma surgeries, providing orthopedic surgeons with a reliable implant for treating tibial fractures that require precise fixation on the medial side.
Key Features:
- Anatomically Contoured Design:Pre-contoured to fit the medial aspect of the proximal tibia, reducing the need for intraoperative adjustments and providing better alignment.
- Low-Profile Plate: Minimizes soft tissue irritation and the risk of tendon impingement, improving post-surgery comfort.
- Locking and Non-Locking Screw Options: Offers versatility in fixation, with locking screws providing additional stability, especially in osteoporotic bones.
- Corrosion-Resistant Materials: Constructed from high-grade stainless steel or titanium, ensuring long-term durability, biocompatibility, and resistance to corrosion.
- Anatomically Contoured Design:Pre-contoured to fit the medial aspect of the proximal tibia, reducing the need for intraoperative adjustments and providing better alignment.
- Low-Profile Plate: Minimizes soft tissue irritation and the risk of tendon impingement, improving post-surgery comfort.
- Locking and Non-Locking Screw Options: Offers versatility in fixation, with locking screws providing additional stability, especially in osteoporotic bones.
- Corrosion-Resistant Materials: Constructed from high-grade stainless steel or titanium, ensuring long-term durability, biocompatibility, and resistance to corrosion.
Benefits:
- Stable Fixation for Complex Fractures: The medial-specific design ensures secure fixation for proximal tibial fractures, reducing the risk of malalignment or delayed union.
- Faster Recovery: Optimized stability and alignment promote effective bone healing, leading to quicker recovery times for patients.
- Minimized Soft Tissue Irritation:The low-profile plate design minimizes the risk of post-operative complications, improving patient comfort and recovery outcomes.
- Versatile Fracture Fixation: Locking and non-locking screws provide flexibility, allowing surgeons to adapt the plate to various types of medial proximal tibial fractures.
- Enhanced Surgical Efficiency:Anatomical contouring reduces the need for intraoperative modifications, saving valuable surgical time.
- Improved Stability in Osteoporotic Bone: Locking screw technology offers secure fixation in patients with compromised bone quality, particularly in elderly or osteoporotic individuals.
- Stable Fixation for Complex Fractures: The medial-specific design ensures secure fixation for proximal tibial fractures, reducing the risk of malalignment or delayed union.
- Faster Recovery: Optimized stability and alignment promote effective bone healing, leading to quicker recovery times for patients.
- Minimized Soft Tissue Irritation:The low-profile plate design minimizes the risk of post-operative complications, improving patient comfort and recovery outcomes.
- Versatile Fracture Fixation: Locking and non-locking screws provide flexibility, allowing surgeons to adapt the plate to various types of medial proximal tibial fractures.
- Enhanced Surgical Efficiency:Anatomical contouring reduces the need for intraoperative modifications, saving valuable surgical time.
- Improved Stability in Osteoporotic Bone: Locking screw technology offers secure fixation in patients with compromised bone quality, particularly in elderly or osteoporotic individuals.
Technical Specifications:
- Plate Thickness:3.5mm
- Material:High-grade stainless steel or titanium, both biocompatible and corrosion-resistant.
- Screw Compatibility: Accepts both 3.5mm and 4.0mm locking and non-locking screws.
- Locking Screw Holes:Equipped with multiple locking screw holes using variable-angle technology for precise screw placement and enhanced fixation.
- Plate Lengths: Available in different lengths to accommodate various fracture patterns and patient needs.
- Indications:Designed for medial proximal tibial fractures, including complex, comminuted, and intra-articular fractures requiring stable fixation.
- Screw Angulation:Variable-angle locking allows for up to 15 degrees of screw angulation, offering surgeons flexibility in fixation.
- Sterilization Compatibility:Suitable for use with standard hospital sterilization protocols.
- Contraindications:Not recommended for fractures extending into the joint without additional joint-specific implants.
Ordering Information:
For detailed product codes, ordering information, and to find out more about how the Meril 3.5mm LPS Medial Proximal Tibial Plate can be integrated into your surgical practice, visit our website or contact a Meril representative.
- Plate Thickness:3.5mm
- Material:High-grade stainless steel or titanium, both biocompatible and corrosion-resistant.
- Screw Compatibility: Accepts both 3.5mm and 4.0mm locking and non-locking screws.
- Locking Screw Holes:Equipped with multiple locking screw holes using variable-angle technology for precise screw placement and enhanced fixation.
- Plate Lengths: Available in different lengths to accommodate various fracture patterns and patient needs.
- Indications:Designed for medial proximal tibial fractures, including complex, comminuted, and intra-articular fractures requiring stable fixation.
- Screw Angulation:Variable-angle locking allows for up to 15 degrees of screw angulation, offering surgeons flexibility in fixation.
- Sterilization Compatibility:Suitable for use with standard hospital sterilization protocols.
- Contraindications:Not recommended for fractures extending into the joint without additional joint-specific implants.
For detailed product codes, ordering information, and to find out more about how the Meril 3.5mm LPS Medial Proximal Tibial Plate can be integrated into your surgical practice, visit our website or contact a Meril representative.